Quick Answer: Syracuse requires building permits for access control installations through the Central Permit Office. You'll need a NYS Security Alarm Installer License, and systems with electromagnetic locks must meet strict egress requirements under the New York State Fire Code. The city charges a $10 alarm permit fee for security system registration through OLEIS.

When Is a Permit Required?

Access control permits are required in Syracuse for:

  • New access control system installations in commercial buildings
  • Electromagnetic door locks on egress doors
  • Card reader or keypad systems connected to door hardware
  • Biometric access systems (fingerprint, facial recognition)
  • Integration with fire alarm or building management systems
  • Systems requiring low-voltage wiring in commercial spaces

Permit Exemptions

You may not need a permit for:

  • Standalone keypad locks not connected to a central system
  • Battery-operated smart locks on residential doors
  • Like-for-like replacement of existing access hardware
  • Minor programming changes to existing systems

Important: Any system with electromagnetic locks on egress doors requires permits and inspections to ensure fire code compliance. When in doubt, contact the Syracuse Central Permit Office at (315) 448-8640.

Contractor Licensing Requirements

New York State requires licensing for security system installations:

NYS Security Alarm Installer License

To install access control systems in Syracuse, you must hold a valid New York State Security Alarm Installer License issued by the Department of State. Requirements include:

  • Training: Complete approved security system coursework
  • Examination: Pass the NYS Security Alarm Installer exam
  • Background check: Fingerprinting and criminal history review
  • Insurance: Proof of liability coverage required
  • Renewal: Every 2 years with continuing education

For complete state licensing information, see our New York Low Voltage License Guide.

Additional Requirements

  • City business registration: Required to operate in Syracuse
  • OLEIS registration: All alarm systems must be registered with Syracuse Police
  • Locksmith license: May be required for door hardware modifications

Electromagnetic Lock Egress Requirements

Access control systems with electromagnetic locks face strict code requirements under the New York State Fire Code. Understanding these requirements is critical for permit approval.

Access-Controlled Egress Doors (NYS Fire Code)

For electromagnetic locks on means of egress doors:

  • Sensor requirement: Motion sensor on egress side must detect approaching occupants
  • Automatic unlock: Doors must unlock upon sensor activation or power loss
  • Manual release: Push button ("Push to Exit") required within 5 feet of door
  • Button height: 40-48 inches above floor
  • Hold open time: Doors must remain unlocked for minimum 30 seconds after manual release
  • Fire alarm integration: Must unlock automatically when fire alarm activates

Door Hardware Requirements

  • Operating devices installed 34-48 inches above finished floor
  • Single-hand operation capability
  • Obvious method of operation in all lighting conditions
  • Power interruption must immediately unlock door
  • Self-closing or automatic closing by smoke detection

Permit Application Process

Step 1: Gather Documentation

Before applying, prepare these materials:

  • Completed building permit application
  • Floor plans showing access point locations
  • Door schedules identifying hardware types
  • Wiring diagrams and riser drawings
  • Equipment specifications and cut sheets
  • Copy of NYS Security Alarm Installer License
  • Proof of insurance

Step 2: Submit to Central Permit Office

Submit your application to:

City of Syracuse Central Permit Office
City Hall Commons, Room 101
201 E. Washington Street
Syracuse, NY 13202
Phone: (315) 448-8640

Applications can be submitted in person or through the online application portal.

Step 3: Plan Review

Code Enforcement reviews plans for compliance with:

  • NYS Building Code
  • NYS Fire Code egress requirements
  • NFPA 101 Life Safety Code
  • ADA accessibility standards
  • Local ordinances

Simple projects may receive "over the counter" approval if plans can be reviewed in under 20 minutes.

Step 4: Register with OLEIS

All security alarm systems in Syracuse must be registered with the Syracuse Police Department through OLEIS (Online Law Enforcement Information System):

  • Fee: $10 per system
  • Each alarm type requires separate OLEIS number
  • Contact: OLEIS@syracusepolice.org or (315) 448-8610

Step 5: Obtain Permit and Schedule Inspections

Once approved:

  • Rough-in inspection (before concealment)
  • Final inspection with system demonstration
  • Fire alarm integration test (if applicable)

Fees and Timeline

Fee Type Amount Notes
Building permit fee Based on project value Minimum $50
Plan review fee 50% of permit fee Commercial projects
OLEIS alarm permit $10 Per system
Re-inspection fee $50 If initial inspection fails

Processing Timeline

  • Simple projects: Same day (over-the-counter approval)
  • Standard commercial: 5-10 business days
  • Complex systems: 10-15 business days

Residential vs. Commercial Requirements

Residential Access Control

For single and two-family homes in Syracuse:

  • Smart locks typically don't require permits
  • Video doorbell systems generally permit-exempt
  • Gate access may require electrical permit
  • Multi-family (3+ units) follows commercial requirements

Commercial Access Control

Commercial projects face additional requirements:

  • Full code compliance for egress doors
  • Fire alarm system integration
  • ADA-compliant hardware heights and operation
  • Emergency power/battery backup requirements
  • Integration with building management systems
  • As-built documentation required

Pro Tips from Experienced Contractors

1. Understand egress code before design. The biggest cause of access control permit delays is non-compliant electromagnetic lock installations. Review NYS Fire Code Chapter 10 before designing any system with mag locks on egress doors.

2. Get OLEIS registration early. Syracuse Police require all security systems to be registered through OLEIS. Complete this registration at the same time as your permit application to avoid delays at final inspection.

3. Document fire alarm integration. If your access control system interfaces with the fire alarm, you'll need to demonstrate automatic unlock on alarm activation during inspection. Have your sequence of operations documented and tested.

4. Consider ADA requirements. Access control hardware must meet ADA standards for mounting height and operation. This is especially scrutinized for public-facing entries and tenant common areas.

5. Plan for power failure scenarios. Inspectors will test what happens when power is lost. Ensure all egress doors fail-safe (unlock on power loss) and document your fail-safe/fail-secure configurations.

Stay Ahead of Permit Activity

Want to know when access control projects hit permits in Syracuse before they reach bid boards?

LVN Signal monitors permit activity across New York and alerts you to opportunities the moment they're filed.

→ Explore LVN Signal

Related Resources

Last updated: January 2025. Requirements may change—always verify with the Syracuse Central Permit Office before beginning work.

Tags

#permits
#new-york
#access-control
#licensing
#syracuse

Join 35,000+ Low Voltage Pros

Get weekly permit updates, tool deals, job opportunities, and industry news. No spam, unsubscribe anytime.