Fire Alarm Permit Requirements in Nashville, Tennessee
Join Low Voltage Nation — Find project opportunities and showcase your company to thousands of industry professionals
Complete guide to fire alarm permit requirements in Nashville, TN. Learn about CAAF permits, Fire Marshal plan review, and Tennessee contractor licensing.
Fire Alarm Permit Requirements in Nashville, Tennessee
Installing fire alarm systems in Nashville requires coordination between Metro Codes, the Fire Marshal's Office, and Tennessee state licensing. This guide covers CAAF permits, plan review requirements, contractor licensing, and the alarm registration process for Davidson County.
Quick Answer: Do You Need a Permit?
Yes, fire alarm permits are required for all new fire alarm system installations, modifications to existing systems, and fire alarm control panel replacements in Nashville. You'll need a CAAF (Commercial Alarm and Fire) permit from Metro Codes, and new systems require Fire Marshal plan review approval before installation.
When Permits Are Required
CAAF Permit Required
- Installing a new fire alarm system
- Adding any devices to an existing system
- Replacing a fire alarm control panel/motherboard
- Relocating existing devices
- System modifications of any kind
Fire Marshal Plan Review Required
- All new fire alarm system installations
- Adding or relocating more than 20 devices to existing systems
- Drawings must comply with adopted fire code and NFPA 72
Emergency Replacements
Emergency panel replacements should be noted during the CAAF permit application. The permit must still be issued, but emergency circumstances are accommodated.
Contractor Licensing Requirements
Tennessee Fire Alarm Contractor License
The Tennessee Alarm Systems Contractors Board (under the Detection Services Licensing Program) regulates fire alarm contractors. Requirements include:
Qualifying Agent Education Options
- Option 1: Post-high-school degree from accredited institution approved by the commissioner
- Option 2: NICET certification (or equivalent approved national certification) plus 3 years of working experience in alarm installation
NICET Certification
For fire alarm classification, the Qualifying Agent must obtain certification by a national training program approved by the Board. NICET fire alarm certification is the standard path.
Examination Requirements
Qualifying Agents must pass PSI exams for each classification applied for. The Tennessee fire alarm license exam is open book.
Licensing Fees
| Fee Type | Amount |
|---|---|
| Company Certification Application | $500 - $600 |
| Employee Registration | $100 |
| License Renewal | $360 (every 2 years) |
| Continuing Education (QA) | 16 hours per renewal |
First Renewal Requirement
For fire alarm licensure, the Qualifying Agent must complete a course in fire alarm installation and monitoring prior to the first renewal (unless this certification was presented for initial licensing).
For detailed licensing information, see our Tennessee Low Voltage License Guide.
Metro Codes CAAF Permit Process
Step 1: Submit Plan Review (New Systems)
For new fire alarm systems, submit shop drawings to the Fire Marshal's Office - Plan Review section before installation:
- Drawings prepared by qualified design professional
- Compliance with adopted fire code and NFPA 72
- Submit to: firemarshal@nashville.gov
Step 2: Apply for CAAF Permit
Apply through Metro Codes E-Permits system:
- Register at epermits.nashville.gov
- Licensed contractors can self-issue permits 24/7
- Homeowners must apply in person
Step 3: Installation
Install system per approved plans (if plan review required) or per NFPA 72 standards.
Step 4: Inspection
Schedule inspection through E-Permits system after installation complete.
Step 5: Alarm Registration
Owner must register system with Alarm Registration Division (see below).
Fire Marshal Plan Review
When Required
- All new fire alarm system installations
- Modifications adding/relocating 20+ devices
Submission Requirements
- Shop drawings prepared by qualified design professional
- Compliance with NFPA 72 National Fire Alarm and Signaling Code
- Compliance with Metropolitan Fire Prevention Code
- Documentation per adopted fire code requirements
Review Hours
Fire Marshal Plans Examiners see customers from 7:30 AM to 3:00 PM. This allows reviewers time to complete daily paperwork.
Contact
- Email: firemarshal@nashville.gov
- Website: Fire and Life Safety Codes Plan Review
Nashville Alarm Registration
All facilities with fire alarm systems must register with Metro Codes Alarm Registration Division.
Requirements
- Registration sticker must be clearly visible on front exterior of building
- Owner/operator responsible for employee training on alarm operation
- Renewal due annually (end of month when initially issued)
- Permits are NOT transferable between locations
Purpose
The alarm registration ordinance (Metropolitan Code §10.60) reduces false alarm responses. False alarms waste emergency resources and may result in penalties.
How to Register
Apply online at epermits.nashville.gov. A 2.3% convenience fee applies to credit/debit transactions.
Fees and Timeline
| Fee Type | Amount | Notes |
|---|---|---|
| CAAF Permit | Varies | Based on system scope |
| Plan Review | Varies | For new systems/major mods |
| Alarm Registration | Annual fee | Required for all systems |
| State Contractor License | $500-$600 | Plus employee registration |
| Plan Review Timeline | Varies | Based on complexity |
| E-Permit Processing | Same day | For registered contractors |
Adopted Codes
Nashville Fire Marshal's Office enforces:
- NFPA 72: National Fire Alarm and Signaling Code
- Metropolitan Fire Prevention Code: Local amendments
- International Fire Code (IFC): As adopted with amendments
- NFPA 70 (NEC): For electrical installation requirements
Check Nashville Fire Department Code Editions for current adopted versions.
Residential vs. Commercial Requirements
Residential Fire Alarm Systems
- CAAF permit required for new systems
- State fire alarm contractor license required
- Alarm registration required if monitored
- Plan review typically not required for basic residential
Commercial Fire Alarm Systems
- CAAF permit always required
- Fire Marshal plan review required for new installations
- Qualified design professional must prepare drawings
- NFPA 72 compliance mandatory
- Alarm registration required
- May integrate with sprinkler system monitoring
Pro Tips from Local Contractors
- Plan review before permit: For new systems, get Fire Marshal approval first to avoid rework
- 20-device threshold matters: Adding/relocating 20+ devices triggers plan review
- Note emergency replacements: Document emergency circumstances on permit application
- NICET is your friend: Certification streamlines the QA qualification process
- Register early: Don't wait for false alarm fees to remind you about registration
- Track first renewal CE: Fire alarm QAs need specific coursework before first renewal
- E-Permits saves time: Registered contractors get 24/7 access and instant permits
Contact Information
Nashville Fire Marshal's Office
- Email: firemarshal@nashville.gov
- Plan Review: Fire and Life Safety Codes Plan Review
- Commercial Fire Alarms: Commercial Fire Alarm Systems
Metro Codes and Building Safety
- Address: 800 President Ronald Reagan Way, 1st Floor, Nashville, TN 37210
- E-Permits: epermits.nashville.gov
- Registration: codes.registration@nashville.gov
Alarm Registration Division
- Website: Alarm Registration
Tennessee Alarm Systems Contractors Board
- Phone: 615-741-9771
- Website: tn.gov/commerce/regboards/alarm
Stay Ahead of Permit Activity
Want to know when fire alarm projects hit permits in Nashville before they reach bid boards?
LVN Signal monitors permit activity across Tennessee and alerts you to opportunities the moment they're filed.
Related Permit Guides
Tags
Join 35,000+ Low Voltage Pros
Get weekly permit updates, tool deals, job opportunities, and industry news. No spam, unsubscribe anytime.