Installing access control systems in Montgomery County requires understanding both county electrical permit requirements and Alabama state licensing. This guide covers everything low voltage contractors need to know about permits, licensing, and compliance for access control projects in Montgomery County.
Quick Answer: Do You Need a Permit?
Generally yes for commercial installations. Montgomery County requires electrical permits for access control systems that involve door hardware modifications, electric strikes, or mag locks. Standalone card readers without electrical integration may be exempt, but most commercial-grade systems will need permitting through Montgomery County Building Inspection.
What Projects Require Access Control Permits?
Montgomery County Building Inspection requires permits for access control installations that include:
- Electric door strikes and magnetic locks
- Motorized gate operators
- Systems with fire alarm integration
- Access systems requiring new electrical circuits
- Door modifications for electronic hardware
- Commercial entry systems with emergency egress
When Are Permits NOT Required?
Permits may not be required for:
- Standalone proximity card readers (no door hardware)
- Wireless access keypads without electrical modifications
- Software upgrades to existing systems
- Badge credential programming
- Maintenance and repair of existing systems
What License Do You Need in Alabama?
Access control contractors in Alabama must hold proper licensing from the Alabama Electronic Security Board of Licensure (AESBL). This is separate from permits—you need the license to legally perform the work.
AESBL License Requirements
| License Type | Requirement | Fee |
|---|---|---|
| Electronic Security License | Application + exam + insurance | $200 initial |
| Qualifying Agent | 3 years experience + exam | Included |
| Annual Renewal | Continuing education | $150/year |
The AESBL license covers access control, security cameras, and intrusion detection systems. You can verify license status or apply through the Alabama Electronic Security Board of Licensure website.
How Do You Apply for a Montgomery County Access Control Permit?
Follow these steps to obtain your permit:
- Prepare documentation - Include system design, door schedules, and electrical requirements
- Submit application - Montgomery County Building Inspection Department
- Pay permit fees - Based on project valuation
- Schedule inspections - Rough-in and final inspection required
- Receive approval - Certificate of completion issued
Contact Information
Montgomery County Building Inspection
100 S Lawrence Street
Montgomery, AL 36104
Phone: (334) 832-1257
What Are the Permit Fees and Timeline?
| Fee Type | Amount |
|---|---|
| Base permit fee | $50-75 |
| Inspection fee | Included |
| Re-inspection fee | $50 |
| Typical processing time | 3-5 business days |
Are Requirements Different for Residential vs Commercial?
Residential Access Control
Residential smart locks, video doorbells, and home access systems typically fall under simpler permit requirements. Many standalone residential systems are permit-exempt, though systems with electric strikes or gate operators may still require permits.
Commercial Access Control
Commercial installations have stricter requirements including:
- ADA compliance for door operators
- Fire alarm system integration requirements
- Emergency egress compliance (fail-safe vs fail-secure)
- Building code requirements for exit hardware
- Detailed system documentation
What Fire Alarm Integration Requirements Apply?
Access control systems that lock doors must integrate with fire alarm systems per NFPA 101 Life Safety Code. When fire alarm activates, secured doors must release automatically. This integration requires coordination between access control and fire alarm contractors.
Systems with fire integration may require additional review from the State Fire Marshal's office.
Pro Tips from Experienced Contractors
- Door hardware matters - Electric strikes and mag locks trigger permit requirements more than readers alone
- Document egress compliance - Show how doors unlock during fire events
- Coordinate with fire alarm contractor - Integration requirements affect both systems
- ADA compliance - Commercial door operators must meet accessibility standards
- Get specifications in writing - Clear scope prevents inspection issues
Stay Ahead of Permit Activity
Want to know when access control projects hit permits in Montgomery County before they reach bid boards?
LVN Signal monitors permit activity across Alabama and alerts you to opportunities the moment they're filed.
Related Permit Guides for Montgomery County
- Security Camera Permits in Montgomery County
- Fire Alarm Permits in Montgomery County
- Structured Cabling Permits in Montgomery County
Summary
Montgomery County access control permits are required for most commercial installations involving door hardware. Contractors must hold an AESBL license to perform the work, then obtain permits through Montgomery County Building Inspection. Processing typically takes 3-5 business days with fees starting around $50-75 for most projects.
Tags
Join 35,000+ Low Voltage Pros
Get weekly permit updates, tool deals, job opportunities, and industry news. No spam, unsubscribe anytime.