Access Control Permit Requirements in Allentown, Pennsylvania
Join Low Voltage Nation — Find project opportunities and showcase your company to thousands of industry professionals
Allentown access control permits depend on electrical work and egress door modifications. Learn Pennsylvania code requirements for mag-locks, fire alarm integration, and delayed egress systems.
Access Control Permit Requirements in Allentown, Pennsylvania
Quick Answer: Allentown typically requires permits for access control installations that involve electrical work, fire alarm integration, or modifications to means of egress. Pennsylvania has strict code requirements for electromagnetic locks and electronic locking systems, including mandatory fire alarm integration and emergency egress provisions. No statewide contractor license is required, but compliance with the Uniform Construction Code is mandatory.
When Is a Permit Required?
Access control permit requirements in Allentown depend on the scope of work and integration with other building systems.
Permit Typically Required
- Electromagnetic locks (mag-locks) on means of egress doors
- Access control systems integrated with fire alarm systems
- Electric strikes requiring new electrical circuits
- Modifications to exit doors or panic hardware
- Card reader systems on fire-rated door assemblies
- Systems requiring local building authority approval
- Delayed egress locking systems
Permit May Not Be Required
- Standalone card readers on interior, non-egress doors
- Battery-powered smart locks on non-fire-rated doors
- Simple keypad entry systems not affecting egress
- Replacement of existing access control hardware in-kind
Under Pennsylvania Code § 403.42, any construction, alteration, or installation of electrical systems regulated by the Uniform Construction Code requires a permit. Contact Allentown's permit office at (610) 439-5996 to confirm requirements.
Pennsylvania Code Requirements for Access Control
Pennsylvania has specific requirements for electronic locking systems that prevent immediate egress. These rules are critical for any access control installation.
Mandatory Approval Requirements
Per Pennsylvania Code, doors equipped with electronic card operated systems or other devices that prevent immediate egress are permitted only if:
- Written approval from the Department of Labor and Industry, Department of Health, or appropriate local building authority
- Manufacturer statement verifying the system will shut down properly during emergencies
- Conspicuous signage with directions for operation posted near the device
Emergency Release Requirements
All doors with electronic locks must open easily and immediately when:
- Fire alarm system is activated
- Heat detector is triggered
- Smoke detector is triggered
- Power failure occurs (fail-safe requirement)
Exit Door Hardware Standards (34 Pa. Code § 50.24)
| Requirement | Specification |
|---|---|
| Panic hardware width | Minimum 1/2 of door leaf width |
| Mounting height | 30 to 44 inches above floor |
| Release force | Maximum 15 pounds |
| Locks during occupancy | No lock preventing egress permitted |
Electromagnetic Lock (Mag-Lock) Requirements
Mag-locks have specific code requirements that must be followed carefully in Allentown and throughout Pennsylvania.
Access-Controlled Egress Doors
| Requirement | Specification |
|---|---|
| Manual release button | Must directly interrupt power to lock |
| Unlock duration | Minimum 30 seconds after button press |
| Button signage | "Push to Exit" required |
| Button height | 40" to 48" above floor |
| Button location | Within 5 feet of doors |
| Motion sensor | Required on egress side to detect approach |
| Fire alarm integration | Must unlock on alarm activation |
Delayed Egress Systems
Delayed egress locking systems have additional restrictions:
- Not permitted: Group A (Assembly), E (Educational), H (High-Hazard) occupancies
- Required: Building must have sprinkler system or smoke/heat detection throughout
- Standard delay: Maximum 15 seconds after 3-second push
- Extended delay: Up to 30 seconds where approved
- Process must be irreversible once initiated
Contractor Licensing Requirements
Pennsylvania does not have a statewide license specifically for access control or low voltage contractors.
Pennsylvania State Requirements
- No state access control license: Pennsylvania does not require a dedicated license for access control installation
- UCC compliance mandatory: All installations must meet Uniform Construction Code standards
- Qualified personnel: Work must be performed by qualified individuals
- Home Improvement Registration: Required for contractors performing $5,000+ annually
Allentown Local Requirements
- Electrical license: May be required for electrical work
- Business license: Required for contracting companies
- Check with Building Standards and Safety for specific requirements
For complete licensing information, see our Pennsylvania Low Voltage License Guide.
Application Process
Step 1: Determine Permit Requirements
Contact Allentown's permit office to confirm whether your specific installation requires permits. Use the Citizen Self Service Portal or call (610) 439-5996.
Step 2: Prepare Documentation
For permitted installations, prepare:
- Site plans showing door and reader locations
- Wiring diagrams
- Equipment specifications and cut sheets
- Fire alarm integration details
- Manufacturer's statement for egress door installations
- UL listing documentation
Step 3: Submit Application
Submit through the Citizen Self Service Portal at allentownpa.gov or in person.
Step 4: Obtain Approvals
For systems on egress doors, obtain written approval from the appropriate authority:
- Allentown Building Standards and Safety
- Pennsylvania Department of Labor and Industry (certain occupancies)
- Pennsylvania Department of Health (healthcare facilities)
Step 5: Schedule Inspection
After installation, schedule inspection to verify code compliance.
Fees and Timeline
| Item | Estimated Cost | Timeline |
|---|---|---|
| Simple access control (no permit) | $0 | Immediate |
| Electrical permit | $50-150 | 3-5 business days |
| Building permit (egress modifications) | Varies by scope | 5-10 business days |
| Fire alarm integration review | May be included | Additional 3-5 days |
Fees are estimates. Contact Allentown permit office at (610) 439-5996 for current fees.
Residential vs. Commercial Considerations
Residential Installations
- Smart locks and keypad systems typically don't require permits
- No egress door restrictions for single-family homes
- Multi-family dwellings have stricter requirements
- HOA rules may impose additional restrictions
Commercial Installations
- Egress door requirements strictly enforced
- Fire alarm integration typically mandatory
- ADA accessibility requirements apply
- Written approval required for electronic locks on egress
- Manufacturer statement required for emergency release verification
Historic District Considerations
Allentown has historic districts where exterior modifications may require additional review:
- Contact Allentown Historical Architectural Review Board (HARB) for exterior installations
- Visible card readers or hardware may need design approval
- Consider concealed or low-profile mounting options
Pro Tips from the Field
Get the Manufacturer Statement: Pennsylvania requires a location-specific manufacturer statement for electronic locks on egress doors. Request this documentation early—it's often overlooked and can delay final approval.
Plan Fire Alarm Integration First: Coordinate with the fire alarm contractor before installation. The access control system must interface properly with the existing FACP for emergency release.
Don't Forget the Signage: "Push to Exit" signs are code-required at manual release buttons. Have signage ready before the inspection.
Understand Fail-Safe vs. Fail-Secure: Egress doors typically require fail-safe locks (unlock on power loss). Interior security doors may use fail-secure. Know which applies to each door.
Document Everything: Keep records of UL listings, manufacturer statements, and inspection approvals for future reference.
Contact Information
Allentown Citizen Self Service Portal (CSS)
Helpline: (610) 439-5996
Online: Citizen Self Service Portal
Building Standards and Safety
City Hall, 435 Hamilton Street, 4th Floor
Phone: (610) 437-7592
Hours: Monday-Friday, 8:00 a.m. - 4:30 p.m.
Stay Ahead of Permit Activity
Want to know when access control projects hit permits in Allentown before they reach bid boards?
LVN Signal monitors permit activity across Pennsylvania and alerts you to opportunities the moment they're filed.
Related Guides
- Pennsylvania Low Voltage License Requirements
- Philadelphia Access Control Permit Requirements
- Pittsburgh Access Control Permit Requirements
- Allentown Security Camera Permit Requirements
- Allentown Fire Alarm Permit Requirements
Last updated: January 2026. Information is provided for general guidance. Always verify current requirements with Allentown Building Standards and Safety before beginning work.
Tags
Join 35,000+ Low Voltage Pros
Get weekly permit updates, tool deals, job opportunities, and industry news. No spam, unsubscribe anytime.